Indoarch O&MProduk

Bomb-Calorimeter

MODEL 5E-C5500 Automatic
Calorimeter
Conforms to Method
•     ASTM D5865, ASTM D4809,GB/T213,GB/T30727,ISO 1928 & ISO9831
•     Precision (1g Benzoic Acid)     0.05% RSD *
•     Measuring range   Up to 40MJ/kg
•     Temp.Resolution     0.0001°C
•     Control Ability     2 Units/ 1 PC available
•     Analysis Time per Sample Dynamic method:10min ; Classical method:15 min
•     Test Per Hour Single control Double control
•     Up to 6 Up to 12
•     Jacket Type Isoperibol
•     Bomb Identification Up to 2 for automatic, several for manual

Online/lab Total Organic Carbon Analyzer TOC

Parameter:
Power Supply: 220V±22V Frequency: 50Hz±1Hz Rated Power:
100W Dimensions: 390mm×194mm×187mm Detection limit:
0.001mg/L (0.001ppm) Maximum tolerance: ±5% Detection range: 0.001mg/L~1.000mg/L (0.001ppm-1ppm) Analyze time: 4min Feedback time: within 15 min Sample temperature: 1~95℃ Ambient temperature: 10~40℃ temperature variation ± 5 ℃ / d or less Flow rate: 0.5 mL/min Relative Humidity≤ 85% Reproducibility tolerance≤ 3% Zero drift ±5% Measurement range drift ±5%


Instruction:
HTY-DI1000C is a high sensitivity and accuracy Total Organic Carbon Analyzer which is a patent product developed by Tailin It is used for detecting TOC concentration in the water. The working principle is to oxidize the organic matters by UV lamp and convert them into CO2. Then the HTY-CI1000C adopts conductivity detection method to detect the concentration of CO2. After detecting the TC (Total Carbon) and TIC (Total Inorganic Carbon), we can get the TOC (Total Organic Carbon) in the water sample. TOC= TC-TIC. HTY-DI1000C TOC analyzer could detect the TOC concentration which is from 0.001mg/L to 1.000mg/L(0.001ppm to 1ppm). It is easy to operate and not need to add any chemical reagent, so that the operators don not need special train or chemical knowledge.

Features:
1. Adopts Ultraviolet(UV) oxidation method, and no requirements to the catalyst and carrier gas;
2. It is most suitable for detecting the TOC in pharmaceutical water because of the unique technology of titanium dioxide catalytic coating spiral pipe;
3. Buzzer alarm for over limit which could prevent the analyzer from mishandling.
4. Online detect devices are for optional which enables the free switch between online and offline detection.
5. Auto sampler is for optional;
6. Meet the system compatibility requirements of USP32-643 and the “TOC Inspection !ct”of CP2010
7. No requirement to any acid reagent, oxidant and carrier gas, no additional daily maintenance cost.
8. It is fast, reliable and easy to operate. The operators don not need any special train or knowledge.
9. Designed for the deionized water which TOC is no more than 1.000mg/L (1ppm).
10. Large memory which could keep 12 months record and the users can look up and print out the record on any date.
11. Fast detection, it is no more than 4 minutes to do one cycle test.
12. Compact design, less weight, portable and less energy consumption.
13. Buzzer alarm for over limit, it can warn the operator when it is over theset result.
14. The system compatibility is easy to be inspected based on the USP<643> and EP<2.2.44>.
15. Large size 320X234 true color display and friendly interface, equipped with RS232 and printer interface.
16. Passed the CMC certification (China Metrology Certification).
Application
The system can be used to detect the total organic carbon concentration in purified water, water for injection(WFI) and deionized water in pharmaceutical industry; it also can on-line monitor (online devices for option) the water system of pharmaceutical industry, ultra-pure water preparation system and chip process in the semiconductor industry, and deionized water preparation process in power plants. It can use for the water clean validation in pharmaceutical and biochemical industries.



Portable Total Organic Carbon Analyzer (TOC)

 

 

Parameters:
•     Requirements on Working Environments
•     1. Power supply: AC 220V/50Hz
•     2; Power: 1000W (when the furnace’s temperature rises)
•     3. Ambient temperature: 0~40 ℃
•     4. Relative humidity: 10—85%
•     5. Set places: indoor
•     6; Gas source: High purity oxygen(≥99;999%)
•     7; High purity water: No carbon dioxide in water (TOC≤0;5mg/L)
•     8. Acid reagent: 10% phosphoric acid
•     9. Instrument placement: there should be 20cm space around for heat
•     dissipation. No items is allowed to be stacked above.


Main technical indicators:
•     1. Measuring range: 0 ~ 1000mg / L (by diluted up to 0 ~ 30,000 mg / L)
•     2. Detection limit: 0.5mg / L (For reference)
•     3; Reproducibility: ≤ 3% (5mg / L or more) ≤ 5% (5mg / L or less)
•     4; Indication error: ≤ 3% (5mg / L or more) ≤ 5% (5mg / L or less)
•     5.Linear: R2> 99.9%
•     6. Response time: 1 to 4 minutes
•     7; Injection volume: 10μL ~ 1000μL
•     8; Carrier gas: oxygen (≥ 99;995%)
•     9.Interface: Carrier inlet: Φ8 PC connection: RS232 External Storage: USB
Insttruction:
•     HTY-CT1000M Total Organic Carbon Analyzer applies 680℃ catalytic
•     combustion oxidation technique. It imports the sample together with the
•     cleaned gas (high purity oxygen) to the high temperature combustion
•     tube and low temperature reaction tube. After going through the high
•     temperature combustion tube, the organic carbon and inorganic carbon
•     among the sample are converted into carbon dioxide by
•     high-temperature catalytic oxidation,and after going through the low
•     temperature reaction tube, the inorganic carbon among the sample is
•     converted into carbon dioxide by acidification. Both kinds of carbon
•     dioxide produced in the reaction tube are imported into non-dispersive
•     infrared gas detector NDIR sequentially, where the CO2 will be detected.
Feature :

•     1. A data terminal can be configured at most eight detection units so that the analyzer can detect eight points simultaneously.
•     2. It realized the function of online multi-point, continuous testing on the water supply system ; which is cost-effective , ease to operate, and can reduce the workload.
•     3. 8 monitoring points data are displaying together, and can be centralized-controlled; and it displays TOC, conductivity and temperature values at the same time.
•     4. Analysis interval time and data storage interval can be set arbitrarily .
•     5. With automatic limit alarm output function, it reminds the operator timely when data anomalies.
•     6. With deadline countdown function of the UV light, it calculates the UV lamp usage time accurately.
•     7. Data can be stored and for reference , and it can save more than 5 years’ data;
•     8. With USB interface, can export data through the U disk.
•     9. A print output.
•     10. Detection mode can be switched off for testing, calibration and validation.
•     11. Without adding acid reagent, oxidants, and any gas, no additional maintenance fees.
•     12. It is simple, fast, and reliable to operate, and users do not need expertise and specialized training.
•     13. Small size, light weight, low energy consumption.
•     14. With water splash preventing design, it can work in wet and high temperatures conditions.
•     15. Compact cabinet designed to meet the demanding requirements of the industrial environment.
•     16. Easy to do the system suitability test that follows USP <643> and
•     EP <2.2.44> and the Chinese Pharmacopoeia Appendix Ⅷ R: TOC detection methods requirements.
Application:
•     TOC detection of surface water, groundwater, sewage, industrial
•     wastewater , used in environmental monitoring, urban drainage,
•     disease control, chemical and power industries.

         1. A data terminal can be configured at most eight detection units so that

         the analyzer can detect eight points simultaneously.

         2. It realized the function of online multi-point, continuous testing on

         the water supply system ; which is cost-effective , ease to

         operate, and can reduce the workload.

         3. 8 monitoring points data are displaying together, and can be

         centralized-controlled; and it displays TOC, conductivity and

         temperature values at the same time.

         4. Analysis interval time and data storage interval can be

         set arbitrarily .

         5. With automatic limit alarm output function, it reminds the operator

         timely when data anomalies.

         6. With deadline countdown function of the UV light, it calculates the

         UV lamp usage time accurately.

         7. Data can be stored and for reference , and it can save more than

         5 years’ data;

         8. With USB interface, can export data through the U disk.

         9. A print output.

         10. Detection mode can be switched off for testing, calibration

         and validation.

         11. Without adding acid reagent, oxidants, and any gas, no additional

         maintenance fees.

         12. It is simple, fast, and reliable to operate, and users do not need

         expertise and specialized training.

         13. Small size, light weight, low energy consumption.

         14. With water splash preventing design, it can work in wet and

         high temperatures conditions.

         15. Compact cabinet designed to meet the demanding requirements

         of the industrial environment.

         16. Easy to do the system suitability test that follows USP <643> and

         EP <2.2.44> and the Chinese Pharmacopoeia Appendix R: TOC

         detection methods requirements.

Application:

         TOC detection of surface water, groundwater, sewage, industrial

         wastewater , used in environmental monitoring, urban drainage,

         disease control, chemical and power industries.

Portable Hydrogen Purity Analyzer

Instrument characteristics:
•     1). Inside place, a longevity life,micro-expending ,the single arm heat lead pond, the adoption hardware a temperature compensate a patent technique;
•     2). Three quantity-distance measure, in keeping with power station etc.;
•     3). -20-50℃ whole scope temperature compensate, responding to quickly;
•     4). The LCD shows the simpleton turns a design, interface amity;
•     5). Internal battery power supply, hold then, convenient,be easy to the operation and calibration ;
•     6). Measure accuracy high, the function stability, hard credibility.
Measure the hydrogen purity and process of metathesis
•     0 to 100%% Hydrogen in Air (Resolution ±0.2%)
•     0 to 100% Carbon Dioxide in Air (Resolution ±0.2%)
•     0 to 100% Hydrogen in Carbon Dioxide (Resolution ±0.5%)
•     Accuracy: Better than 0.2% of full scale.
•     Firm Thermal conductance pool detection of the macrobiotic life
•     Fast respondent 、good line shape degree、steady reading
•     Built-in flow meter and The controlling flow valve
•     Using simply and testing convenient
•     Using LCD and rechargeable battery
•     Instrument in the absence of gas flowing can operate safely
Purity detection sensors:
•     HNP thermostatic type hot-pool having temperature compensation function
•     Measure range : 0 to 100% Content of H2 in Air
•     0 to 100% Content of H2 in CO2
•     0 to 100% Content of CO2 in Air
•     Accuracy:±0.2% (In special scope)
•     Repetitive:±0.2% (In special scope)
•     Storage capacity: 80 records
•     Show: Mega -LCD and picture menu
•     Ambient temperature: -30℃ to 50℃
•     Response speed: 5~15S
•     The pressure of work: 0~1MPa
•     Electronic meters: Quality meters, 0~1000 ml/min
•     Gas-in: 20~200ml/min
•     Power supply: AC 240 V/50 Hz, The charged-up batteries inside.
•     Weight: 2.5kg
•     Size: 310 × 250 × 100mm3

Laboratory Sodium Analyzer

Feature :
Advanced 32 bits embedded MCU
technology . SMT and integrative design .
ABS waterproof enclosure . Membrane touch keys . CPU intelligent design . LCD display .
User interface language:English .
Simultaneous display of multiparameters . Automatic or manual temperature
compensation . Several calibration methods available . 4 individually password protected . Datalog with time and date stamp .
Intelligent measurement, auto judge as calibration is stablease operation .
Universal power supply for worldwide operation(100~240)V